Back to Journals » Clinical Ophthalmology » Volume 17
Twist Technique to Stop Fluid Leakage and Fixate the Eye During Bimanual Cortex Removal in Phacoemulsification
Authors Khaled H , Haj Najeeb B
Received 16 February 2023
Accepted for publication 6 April 2023
Published 14 April 2023 Volume 2023:17 Pages 1147—1149
DOI https://doi.org/10.2147/OPTH.S405293
Checked for plagiarism Yes
Review by Single anonymous peer review
Peer reviewer comments 2
Editor who approved publication: Dr Scott Fraser
Hassan Khaled,1,* Bilal Haj Najeeb2,*
1Magrabi Eye & Ear Hospital, Makkah, Saudi Arabia; 2Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
*These authors contributed equally to this work
Correspondence: Hassan Khaled, Magrabi Eye & Ear Hospital, The Holy Mosque Street, Al Murasalat, Makkah, 24247, Saudi Arabia, Email [email protected]
Abstract: Leakage of fluid through the side port during aspiration of the cortex leads to instability of the anterior chamber. In addition, eye movement may cause an unintended pulling of the irrigation probe out of the corneal wound resulting in collapsing of the anterior chamber. Both situations could pose a challenge to the surgeon and increase the risk of serious intraoperative complications. Therefore, we describe a simple effective maneuver to avoid these conditions during bimanual cortex removal and viscoelastic washout. In Khaled technique, rotating the irrigation probe outwards causes complete occlusion of the lumen of the side port and a simultaneous stabilization of the anterior chamber. Twisting the incision by the irrigation probe also offers better fixation of the eye at the edge of the side port and a subsequent reduction of eye movement.
Keywords: irrigation probe, irrigation/aspiration, cataract surgery, cortex removal, phacoemulsification
Introduction
Successful aspiration of the cortex during phacoemulsification surgery is crucial to ensure a precise position of the intraocular lens and a reduction of the postoperative inflammation.1 To achieve a safe cortex aspiration, a stable anterior chamber (AC) is mandatory.2 One common reason for fluctuation of the depth of the AC and the fluttering of the posterior capsule is the outflow of fluid through the side port. This unavoidable leakage may occur even when the size of the side port is equal to that of the irrigation probe. Subsequently, an unstable AC promotes serious intraoperative complications during cortex removal such as zonular dialysis, posterior capsule rupture and vitreous loss.
In addition, eye movement could cause an inadvertent pulling of the irrigation probe out of the corneal incision during the irrigation aspiration (I/A) of the residual cortex resulting in collapsing of the AC and unfavorable complications.3 Unfortunately, to date there has been no simple maneuver to overcome these two intraoperative problems. Therefore, we describe how to manage these situations using one novel easy technique.
This study was conducted in accordance with the tenets of the Declaration of Helsinki. No ethical approval was needed as we report on one case study. An informed consent was obtained from the study participant.
Surgical Technique
Once the surgeon observes leakage through the side port after introducing the 20- gauge irrigation probe, rotating the irrigation probe outwards about 50 degrees from its radial position can stop the leakage (Figure 1a–c), (Video 1). This twist maneuver causes occlusion of the side port and subsequently a fast stabilization of both AC and posterior capsule. Also, it helps the surgeon to fixate the eye by providing two support points, namely the proximal outer edge and the distal inner edge of the corneal incision (Figure 1d). Of course, this technique does not prevent a simultaneous clean-up of the cortex and the viscoelastic substance using the 20-gauge aspiration probe at the second side port. During twisting the incision, the surgeon should be aware not to touch the corneal endothelium or the iris with the tip of the irrigation probe (Figure 1a–c), (Video 1).
Discussion
In addition to the traditional bimanual I/A technique,4 many methods have been described to aspirate the cortex such as the use of coaxial I/A. Nonetheless, removal of the subincisional cortex could be challenging, in particular when the capsulorehxis is not quite large. Also, posterior capsule rupture is more prevalent in the coaxial I/A technique than in the bimanual technique.5,6 Simcoe I/A cannula is another option. However, the side port should be enlarged.
To minimize the leakage, partial hydration of the side port could be an alternative way. However, it is time-consuming, causes corneal haziness which may affect the view during cortex removal. Also, it could be complicated with unfavorable Descemet membrane detachment, and it does not provide a simultaneous fixation of the eye as it does with our technique. Notably, entering the AC without applying any pressure on the inner side of the wound also reduces leakage and prevents the shallowing of the AC. AC maintainer can sometimes be used to provide more stability to the AC, but an additional corneal incision is needed. Compared to the previous techniques, our simple twist maneuver provides an immediate occlusion of the leaking port and maintains a closed eye system for an uneventful aspiration of the residual cortex. Interestingly, this procedure is cost-free, easy to learn and not time-consuming.
The second benefit of our technique is that movement of the eye is reduced, as twisting the incision offers two contact points between the irrigation probe and the side port (Figure 1d). Thus, drawing back the probe out of the eye and a subsequent collapse of the AC is much less likely. It is especially important when the patient cannot fixate on the light of the microscope under topical anesthesia.3 Moreover, this maneuver does not affect the integrity and self-sealing property of the side ports (Figure 1e).
Conclusion
Khaled twist technique offers several advantages to maintain a stable AC compared to other maneuvers. In addition, this simple, cost-free maneuver provides more fixation of the eye and reduces the rate of complications during cortex removal.
Funding
This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Disclosure
HK: none, BHN: RetInSight, unrelated to this study.
References
1. Schwartz SG, Holz ER, Mieler WF, et al. Retained lens fragments in resident-performed cataract extractions. CLAO J. 2002;28(1): 44–47.
2. Geng W, Lin W, Song P, et al. Effect of anterior chamber instability during phacoemulsification combined with intraocular lens implantation. J Ophthalmol. 2022;2022:1–10. doi:10.1155/2022/2848565
3. Brogan K, Dawar B, Lockington D, et al. Intraoperative head drift and eye movement: two under addressed challenges during cataract surgery. Eye. 2018;32(6):1111–1116. doi:10.1038/s41433-018-0047-x
4. Brauweiler P. Bimanual irrigation/aspiration. J Cataract Refract Surg. 1996;22(8):1013–1016. doi:10.1016/S0886-3350(96)80112-X
5. Ti S-E, Yang Y-N, Lang SS, et al. A 5-year audit of cataract surgery outcomes after posterior capsule rupture and risk factors affecting visual acuity. Am J Ophthalmol. 2014;157(1):180–185.e1. doi:10.1016/j.ajo.2013.08.022
6. Bai H, Yao L, Wang H. Clinical investigation into posterior capsule rupture in phacoemulsification operations performed by surgery trainees. J Ophthalmol. 2020;2020:1317249. doi:10.1155/2020/1317249
© 2023 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.
Recommended articles
Correlations of Immediate Corneal Tomography Changes with Preoperative and the Elapsed Phaco Parameters
Haddad JS, Borges C, Daher ND, Mine A, Salomão M, Ambrósio Jr R
Clinical Ophthalmology 2022, 16:2421-2428
Published Date: 4 August 2022
Impact of Cataract Surgery on IOP and Ocular Structures in Normotensive Patients and Primary and Exfoliation Open-Angle Glaucoma Patients
Xirou V, Xirou T, Siganos C, Ntonti P, Georgakopoulos C, Stavrakas P, Makri OE, Kanakis M, Tsapardoni F, Fragkoulis I, Garnavou-Xirou C, Kozobolis V
Clinical Ophthalmology 2023, 17:1047-1055
Published Date: 5 April 2023